For applications with limited space
TORRIX 6, with its probe diameter of only 6 mm and a float diameter of only 27 mm, is ideal for applications with smaller tanks. Another advantage is that there are no dead zones in the upper and lower areas. The starting point of the measurement is only defined by the size of the float; therefore the entire volume can be measured and used.
- Length: 100 mm to 1,000 mm
- Tube diameter: 6 mm
- Smallest float diameter: 27mm
- Process temperature up to 125 °C.
- ATEX and IECEx approval for use in Ex-Zone 0
Applications
Accessories
HPH Ex d
High Pressure Connection Housing
- On site display for level indication
- Corrosion resistant (stainless steel 1.4305)
- Adjustable display
- 10 mm LED display
- Easy to install
- Intrinsically safe power supply for Ex-Zone 0
- ATEX and IECEx approval
- Robust design
UM-X
The control unit in a field housing for continuous level sensors
- Easy menu-driven graphical user interface
- Can be used with all sensors with a 4-20 mA interface
- Intrinsically safe electrical circuit with ATEX approval (Ex ia)
- Combined with TORRIX, approved as an overfill prevention
- fulfilling the German Water Resources Act (WHG)
- Pump control (alternating)
- Continuous displaying the filling level
- Filling levels can be displayed in mm, inches, % or mA
Ex REPEATER/POWER SUPPLY
PR Electronics PRetrans 5104B
- Current loop : <28 V, max. 600 Ohm
- Output : 4 - 20 mA
- Auxiliary power : 24 - 230 V DC/AC
- Hilfsenergie : 24 bis 230 V DC/AC
- Snap-on mounting for DIN-rail
Application Examples
Below are examples of where the TORRIX is being used successfully
Storage Tanks and Storage Containers
TORRIX is ideally suited for measuring in all non-adhesive liquids and almost all tank geometries. There is no need to adjust the sensor to the liquid or the shape of the tank. Another advantage is that there are no dead zones in the upper and lower areas. The starting point of the measurement is only defined by the size of the float; therefore the entire volume can be measured and used.
Pilot plant and prototype systems
The TORRIX 6 with his probe diameter of 6 mm and float diameter of 27 mm is ideal for applications in smaller containers. Unlike most sensors, TORRIX measures in the upper and lower region with no dead zone with the threshold point defined only by the float. The TORRIX is ideal in applications where frequent changes of media are needed as it does not require adjustment.
Contact Information
Sales Engineer
Kevin Biehl
Phone: +49/40/39 82 07 - 83
Fax: +49/40/390 63 - 39
E-Mail: kevin.biehl@fafnir.de
Customer and Technical Support
Michael Stier
Phone: +49/40/39 82 07 - 14
Fax: +49/40/390 63 - 39
E-Mail: michael.stier@fafnir.de
Specifications
Equipment Type | Magnetostrictive Level Measurement |
---|---|
Liquid | Chemicals, Fuel, Solvents, Water |
Vessel | Laboratory Bottle, Waste Container |
Measuring range | 100.00 mm up to 10 000.00 mm |
Stem diameter | 6.00 |
Process Connection | Fitting, None |
Temperature | -40.00 °C up to 125.00 °C |
Pressure | -1.00 bar up to 16.00 bar |
Certification | ATEX, IECEx, None |
Signal output | 4-20 mA, HART |
Power Supply | 10 to 30 VDC, 15 VDC, 24 VDC |
Additional criteria | Dry run protection, Electropolished |