TORRIX Bypass

TORRIX Bypass

For bypass applications with magnetic level indicator

The TORRIX bypass is the ideal sensor for level measurement in tanks with magnetic level indicators. The TORRIX is mounted on the outside of the bypass, and picks up the magnetic field and delivers the level inside the bypass, without any contact with the liquid. Many magnetic level indicators can be retrofitted with a TORRIX.

  • Maximum length: 200 mm up to 6000 mm
  • Process temperature up to 450 °C.
  • SIL 2 (proven in use)
  • ATEX and IECEx approval for use in Zone 0
FAFNIR Process Technology

HPH Ex d

High Pressure Connection Housing

  • On site display for level indication
  • Corrosion resistant (stainless steel 1.4305)
  • Adjustable display
  • 10 mm LED display
  • Easy to install
  • Intrinsically safe power supply for Ex-Zone 0
  • ATEX and IECEx approval
  • Robust design

    DOWNLOAD  

UM-X Transducer

UM-X

The control unit in a field housing for continuous level sensors

  • Easy menu-driven graphical user interface
  • Can be used with all sensors with a 4-20 mA interface
  • Intrinsically safe electrical circuit with ATEX approval (Ex ia)
  • Combined with TORRIX, approved as an overfill prevention
  • fulfilling the German Water Resources Act (WHG)
  • Pump control (alternating)
  • Continuous displaying the filling level
  • Filling levels can be displayed in mm, inches, % or mA

    DOWNLOAD  

Ex REPEATER/POWER SUPPLY

Ex REPEATER/POWER SUPPLY

PR Electronics PRetrans 5104B

  • Current loop : <28 V, max. 600 Ohm
  • Output : 4 - 20 mA
  • Auxiliary power : 24 - 230 V DC/AC
  • Hilfsenergie : 24 bis 230 V DC/AC
  • Snap-on mounting for DIN-rail
Storage Tanks and Storage Containers

Bypass applications with magnetic level indicator

In magnetic level indicator applications, the magnetic indicators are actuated by the magnetic field of a float in the interior of the bypass. The magnetic field of this float can also be measured by a TORRIX which is mounted on the exterior of the bypass. The TORRIX can therefore measure the level without media contact and without additional intervention in the process tank. Many magnetic level gauges can be retrofitted with a TORRIX.

Download Order code 

Sales Engineer

Kevin Biehl
Phone: +49/40/39 82 07 - 83
Fax: +49/40/390 63 - 39
E-Mail: kevin.biehl@fafnir.de

Customer and Technical Support

Michael Stier
Phone: +49/40/39 82 07 - 14
Fax: +49/40/390 63 - 39
E-Mail: michael.stier@fafnir.de

Specifications:
Equipment Type
Magnetostrictive Level Measurement
Liquid
Acids
Chemicals
Fuel
Solvents
Water
Measuring range
200.00 mm up to 6 000.00 mm
Stem diameter
12.00
Process Connection
None
Temperature
-65.00 °C up to 450.00 °C
Certification
ATEX
IECEx
None
Signal output
4-20 mA
HART
Power Supply
10 to 30 VDC
15 VDC
24 VDC
Addtitional criteria
Dry run protection
Electropolished

Ordering information